Boiler MJ-1

Parameters

Construction: Mj-1 boilers are tested construction adapted for upper combustion of solid fuels, with big load chamber and easy cleaning of convection tubes (cleaning in charging end of the boiler). Construction of the boiler is designed so that the flame from combusting fuel could circulate the greatest possible boiler area. Boiler is equipped with traveling cast-iron grate and water grate, which takes efficiently the thermal energy from burning heating fuel. Due to using four water lamellas placed horizontally, they are maximally energetically used, taking advantage of natural flue draught.



All supported fuel types

wegiel.pnghard coal
drewno.pngweathered wood

Certified boiler plate

blacha_2.pngCertified boiler plate of sheet gauge 6 mm [P265GH]

Main functions

  • simple constructions,
  • cast-iron traveling grates, 
  • solid quality of work (body  frame made of boiler plate 6 mm),
  • reliability,
  • oblique door facilitating fuel load,
  • door hold down adjustment
  • Rodzaje kotłów (parametry techniczne)

    Parameter   MJ-1
    Heating surface 0,8 1,1 1,3 1,5 1,7 2,0 2,5 3,0
    Nominal heating power kW 10 12 14 17 20 24 28 35
    Max temperature of water in boiler °C 95 95 95 95 95 95 95 95
    Width mm 370 370 390 450 460 460 480 510
    Length mm 450 450 460 460 490 570 630 650
    Height mm 1230 1230 1230 1230 1230 1230 1230 1230
    The scope of heated area do 60 do 90
    90-110 110-130 130-260 160-180 180-220 220-280
    Min. section of chimney tube cm x cm/mm 17x17 Ø200 17x17 Ø200 17x17 Ø220 18x18 Ø240 20x20 Ø250 21x21 Ø260 22x22 Ø280 23x23 Ø280